Light control system of the flaslamp-resistant climate test chamber

Flashlamp- resistant climate test chamber have Equipped a light sensor probe radiation of the Irradiation, also known as the Solar Eye, a high_precision light control system, it can be the lamp or light energy of any other changes caused by the decline to compensate in time. Solar Eye allows selecting the appropriate light irradiance during the test, and even can choose the equivalent irradiance at noon in summer sunlight. Solar Eye continuously monitor light irradiance in irradiation chamber, and by adjusting the lamp power, precision will be maintained in the work setting irradiance value. Due to long working hours, when the irradiance falls below the set value, the lamp needs to be replaced with a new one, in order to ensure normal irradiance.


specification:
Temperature range: -100 ℃℃ ~ + 200 ℃
Humidity Range: 0 ~ 99.9% RH
Rain time setting range: 0 to 99 hours 59 minutes interval (off) Adjustable rain
Illumination time setting range: 0 to 99 hours 59 minutes interval (off) illumination adjustable
Gel time setting range: 0 to 99 hours 59 minutes interval (off) Adjustable Gel
Blackboard temperature and turntable can be set

Precautions of color assessment cabinet


1. When you press the source button on the control panel, you should observe the power display LED display status, such as the LED light does not shine, prove the standard source of color assessment cabinet have the problem problematic, probably had a bad bulb or lamp, or its internal circuit or an electronic component damage or aging, it should notify the measurement engineer or related personnel be repaired,After the machine is OK ,you can use the machine.

2. When using the inner box should be clean, ban placed vulnerable chemicals of the flammable and explosive products in inside boxes (such as alcohol, water and other items).

3. Before using a standard light source color to be confirmed color assessment cabinet whether by check and within the calibration validity.

2016年1月5日星期二

How to measure the noise of the temperature & humidity test chamber

Measurement as follow:
The position of the measuring point: the measurement point is located in front of the device axis 1m distance away (device front vertical), the height from the ground to a height of 1/2 of the device, but the maximum height from the ground is not more than 1.5m, the minimum height of not less than 1m.

Measurement: 
1, before the open the temperature &humidity test chamber, measuring measurement point Aweighted sound pressure level of the background noise. 

2, the device under test load and maximum radiated noise working conditions normal and stable operation, the use of the Aweighted network measurements level and Aweighted sound pressure level , the microphone should be positive for the test equipment, the use of soundlevel meter "slow "time weighting characteristics were measured, sound pressure level is the average count within the observation period (for maximum or minimum occasional not be considered). To avoid affecting the operation's body reflection measurements, the operating distance microphone should be at least greater than 0.5m. 

3. Record the measured values, according to Table 1 as amended, temperature & humidity test chamber is running noise A-weighted sound pressure level.